DirectLOGIC 305 Programmable Logic Controller
The DL305 PLC series is a small modular PLC that has been
marketed by various name-brand PLC manufacturers for over 20
years.
This Koyo design revolutionized the small PLC market, and is still a good performer
and a great value.
Over 3,000,000 Koyo 305 modules
have been sold, which shows that these modules are
extremely reliable and well-suited for many applications.
1983
to 2007
- Three standard CPUs to choose from, including the D3-350 CPU
with PID control and two communication ports
- Specialty CPUs to convert a DL305 system into an RTU for
Optomux, Pamux, or to allow BASIC programming for custom
applications
- Five, eight and 10-slot bases
- 110/ 220 VAC or 24 VDC power supply
- AC, DC inputs
- AC, DC, and relay outputs
- Eight or 12-bit analog input/output
- Specialty modules such as ASCII/ BASIC module, high-speed
counter, and communication interface module (for use with D3-330
and D3-340 CPUs)
NOTE: PID (Proportional, integral,
derivative) control: Control algorithm that is used to closely
control processes such as temperature, mixture, position, and
velocity. The proportional portion takes care of the magnitude of
the error. The derivative compensates for the rate of error change.
The integral takes care of small errors over time.
The D3-350 CPU has a killer instruction set (compatible with the
DL405, DL205, DL105, and DL05 PLC families) and some super practical
communications.
The D3-350 CPU uses a simplified I/O
addressing method, and can access up to twice as much local I/O as
any other DL305 configuration (when installed in a system with -1
bases).
Features include:
- Real-time calendar/ clock and historical error logging
- Trigger events in logic or time-and-date stamp error
conditions
- Four super-easy PID loops with 'auto-tune' allow the CPU to
automatically determine the near-optimum loop settings
- Automatic loop scheduling reduces logic required to operate
loops
- Fill-in-the-blank chart for alarms and ramp/ soak
- Programming software includes loop tune screen with trending
- Two communication ports include built-in remote I/O master for
long-distance I/O expansion
NOTES:
New option modules may not be supported by CPUs
purchased prior to the modules release.
Be sure to check for the
latest firmware for your PLC. You can refer to the module
specification page on our Web site for this information, or find it
in our free catalog.
Here is the direct link to the Firmware Upgrade section of our Web site where
you can find the firmware revision histories, the latest files and
tools required to download the firmware into your CPU.
|
|
Cross-check legacy PLC parts with our DirectLOGIC DL305
PLC
.
Our part# and price |
Legacy part number |
DirectLOGIC
305 |
|
SIMATIC ®
TI /
FACTS |
Koyo |
GE Fanuc |
|
|
305-01DA |
E-01DA |
IC610MDL166 |
|
|
305-01AD |
E-01AD |
IC610MDL116 |
D3-04TAS |
|
305-21T |
E-21T |
IC610MDL176 |
D3-04TD1 |
|
305-12T |
E-12T |
IC610MDL153 |
D3-05B-1 |
|
305-02B |
E-02B |
IC610CHS110
IC610CHS101 |
D3-05BDC |
|
305DC-02B |
E-02B-C |
IC610CHS114 |
D3-08B-1 |
|
305-05B |
E-05B |
|
D3-10B-1 |
|
305-04B |
E-04B |
IC610CHS120
IC610CHS130 |
D3-10BDC |
|
305DC-04B |
E-04B-C |
IC610CHS124
IC610CHS134 |
D3-08NA-1 |
|
305-20N |
E-20N |
IC610MDL125 |
D3-08NA-2 |
|
305-22N |
E-22N |
IC610MDL127 |
D3-08ND2 |
|
305-01N |
E-01N |
IC610MDL101 |
D3-08NE3 |
|
305-02N |
E-02N |
IC610MDL111 |
D3-08SIM |
|
305-01S |
E-01S |
IC610MDL124 |
D3-08TA-1 |
|
305-20T-1 |
E-20T-1 |
IC610MDL179 |
D3-08TA-2 |
|
305-20T |
E-20T |
IC610MDL175 |
D3-08TD1 |
|
305-10T |
E-10T |
IC610MDL151 |
D3-08TD2 |
|
305-50T |
E-50T |
IC610MDL155 |
D3-08TR |
|
305-01T |
E-01T |
IC610MDL180 |
D3-16NA |
|
305-25N |
E-25N |
IC610MDL129 |
D3-16ND2-1 |
|
305-05N |
E-05N |
IC610MDL107 |
D3-16ND2-2 |
|
305-35N |
E-35N |
IC610MDL106 |
D3-16ND2F |
|
305-05NH
TI305-05NH |
E-05NH |
|
D3-16NE3 |
|
305-55N |
E-55N |
IC610MDL112 |
D3-16TA-2 |
|
305-25T |
E-25T |
|
D3-16TD1-1 |
|
305-15T |
E-15T |
IC610MDL157 |
D3-16TD1-2 |
|
305-35T |
E-35T |
IC610MDL156 |
D3-16TD2 |
|
305-55T |
E-55T |
IC610MDL158 |
D3-16TR |
|
305-05T |
E-05T |
IC610MDL182 |
D3-232-DCU |
|
305-03DM |
E-03DM |
|
D3-330 |
|
330-37
325-07 |
SR-22 |
IC610CPU106
IC610CPU104 |
D3-330 |
|
|
|
IC610CPU105 |
|
|
330S-37 |
SA-22 |
|
D3-340 |
|
335-37 |
SR-23A |
|
D3-422-DCU |
|
305-02DM |
E-02DM |
IC610CCM105 |
D3-CPU-UV |
|
2587681-8021 |
|
IC610ACC155 |
D3-D4-BAT |
|
305-BATT |
RB-5 |
IC610ACC150 |
D3-DSCBL-2 |
|
VPU200-3605 |
|
|
D3-EXCBL |
|
305-05J |
E-05J |
IC610CBL101 |
D3-FILL |
|
305-DMY |
E-DMY |
IC610MDL100 |
D3-HP |
|
305-PROG |
R-23P |
IC610PRG105 |
D3-HPCBL |
|
305-15PJ-1 |
E-15PJ-1 |
IC610CBL102 |
|
|
305S-PROG |
A-23P |
|
|
|
305-01Z |
E-01Z |
IC610MDL110 |
D3-MBZL |
|
305-BZL |
E-BZL |
IC610PRG190 |
|
|
305-22P |
C-22P |
IC610PER154 |
|
|
305-10D |
F-10D |
IC610TCU100 |
|
|
|
U-03RM |
|
|
|
|
U-03RS-NT2 |
|
|
|
|
U-03RS-N1 |
|
|
|
|
U-03RS-T1 |
|
|
|
|
U-03RS-NT1 |
|
F3-04ADS |
|
305-4ADC-S |
|
IC610ADC144 |
F3-04DA-1 |
|
305-4DAC |
|
IC610DAC124 |
F3-04DAS |
|
305-4DAC-S |
|
|
F3-08AD-1 |
|
305-8ADC |
|
IC610ADC128 |
F3-08TAS |
|
305-TI-8AC-S
305-8AC-S |
|
|
|
|
305-8AD590 |
|
|
F3-08THM-1 |
|
305-8THM-1 |
|
|
F3-08THM-2 |
|
305-8THM-2 |
|
|
|
|
305-8THM-E |
|
|
F3-08THM-J |
|
305-8THM-J |
|
|
F3-08THM-K |
|
305-8THM-K |
|
|
|
|
305-8THM-R |
|
|
|
|
305-8THM-S |
|
|
|
|
305-8THM-T |
|
|
F3-08TRS-1 |
|
305-8RLY-I |
|
IC610RLY110 |
F3-08TRS-2 |
|
305-9RLY-I |
|
|
F3-16AD |
|
305-16ADC |
|
IC610ADC120 |
F3-16ND3F |
|
305-16DC |
|
IC610INP100 |
F3-16TA-2 |
|
305-16AC |
|
IC610VAC115 |
F3-AB128 |
|
305-12ABM
305-6ABM-1 |
|
IC610ASC268 |
F3-AB128-R |
|
305-64ABM-RM |
|
IC610ASC254 |
F3-AB128-T |
|
305-64ABM-TM1
305-6ABM-TM1
305-12ABM-TM |
|
IC610ASC252 |
F3-FILL-CB |
|
305-DMY-TB
305DMYCB
305-DMY-CB |
|
|
F3-OMUX-1 |
|
305-CPU |
|
|
F3-OMUX-2 |
|
305-OPTO |
|
|
|
|
305-CPU-R |
|
|
F3-PMUX-1 |
|
305-OPMX-1 |
|
|
|
|
305-CPU-RTU |
|
|
FA-UNICON |
|
305-DCU-C
305-DCU-C-1
305-DCU-S |
|
IC610PER105 |
|